Stiffness coefficients

The stiffness coefficients and their usage in the steel connections are defined by the EN 1993-1-8 Article 6.3.1 Table 6.9 and 6.10.:

Coefficient

Basic component

Formula

k1

column web panel in shear

2

column web in compression

k3

column web in tension, single bolt row in tension

k4

column flange, single bolt row in tension

k5

endplate, single bolt row in tension

K10

bolts, single bolt row in tension

with

Avc

the shear area of the column

z

the lever arm

b

the transformation parameter

beff

the effective width of the column web

dc

the clear depth of the column web

leff

the smallest effective length for the bolt (minimum of individual and relevant partial effective lengths)

m

the distance bolt to beam/column web

As

the tensile stress area of the bolt

Lb

 

the elongation length of the bolt

In SCIA Engineer the usage of the stiffness coefficients is related to a connection type:

For a bolted beam-to-column connection, the following coefficients are used :

Coefficient

Present

keq

k1

x

 

k2

x

 

k3

x

x

k4

x

x

k5

x

x

K10

x

x

For a welded beam-to-column connection, the following coefficients are used :

 

Coefficient

Present

keq

k1

x

 

k2

x

 

k3

 

 

k4

x

 

k5

 

 

K10

 

 

When a column minor axis configuration is used, the values for k1 and k2 are replaced by ki, the stiffness coefficient in the tension or the compression zone of the column web in bending and punching. The value for ki is given by (see Ref.[21]) :

with

c1

1.50

c2

1.63

10≤u≤50

0.08≤β≤0.75

0.05≤α≤0.2

 

The factor krot is equal to 1 if the rotation of the column flanges restrained

For a bolted plate-to-plate connection, the following coefficients are used :

Coefficient

Present

keq

k1

 

 

k2

 

 

k3

 

 

k4

 

 

k5 Left side

k5 Right side

x

x

x

x

K10

x

x

A welded plate-to-plate connection is considered as rigid.

For a column base, the following coefficients are used :

Coefficient

Present

keq

k1

 

 

k2

 

 

k3

 

 

k4

 

 

k5

x

x

K10

x

x

kc

x

 

The value of Lb in coefficient k7 is taken as the free length of the anchor bolts plus the free length of embedded part. The free length of the anchor bolts is equal to the base plate thickness plus the head height of the anchor bolt. The free length of the embedded part is equal to 8-times the anchor diameter.

The stiffness kc is the stiffness coefficient for the compression zone in the concrete block.

with

Afl

the bearing area under the compression flange

Ec

the E modulus of concrete

(Ec in Gpa, fck in Mpa)

E

the Young modulus (of steel)

heq

the equivalent height

where aeff and beff are based on the rectangle for determining Afl

Afl=aeff x beff

SCIA web

Downloads

SCIA is part of the Nemetschek group