Scaffolding coupler check

The scaffolding couplers according to EN 12811-1 Annex C Ref.[23] are provided by default within SCIA Engineer.

The interaction check of the couplers is executed according to EN 12811-1 article 10.3.3.5.

The interaction equations are summarised as follows:

Coupler type

Interaction equation

Right angle coupler

 

Friction sleeve

 

Fsk

Characteristic Slipping force

Taken as Nxk and Vzk of the coupler properties

2Fsk = Nxk + Vzk

Fpk

Characteristic Pull-apart force

Taken as Vyk of the coupler properties

MBk

Characteristic Bending moment

Taken as Myk of the coupler properties

N

Normal force

Vy

Shear force in y direction

Vz

Shear force in z direction

My

Bending moment about the y axis

Safety factor taken as γM0 of EN 1993-1-1 for steel couplers

Safety factor taken as γM1 of EN 1999-1-1 for aluminium couplers