First you get an overview of the input data for the design:

Longitudinal reinforcement

The design of longitudinal reinforcement to resist N, My and Mz is done according to the Ultimate Limit State requirements. Design method is selected based on type of member (beam x column) and according to the acting load. There is not any limit for type of cross-section (formerly for columns rectangle and circle) nor for load type (formerly for beams - My or Mz).

In case the required area of reinforcement exceeds the available space on one layer, more layers (with adapted lever arm) are automatically generated. Designed reinforcement is automatically recalculated to real bars afterwards.

Shear reinforcement

The design of shear reinforcement to resist Vy and Vz is done according to the ULS requirements. Formerly, there was possibility to design shear reinforcement just for Vy or Vz.