Settings for beam slabs

Beam Slab

Longitudinal

Check min. bar distance

Description

Setting if minimal clear bar distance of longitudinal reinforcement for beam slab is checked or not.

Default Check box YES

Code

8.2(2)

Figure

Minimal bar distance

Description

Additional limit for minimal clear bar distance of longitudinal reinforcement for beam slab

Default Edit box slb,min = 20 mm

Code

8.2(2)

Figure

Check max. bar distance

Description

Setting if maximal centre-to-centre bar distance of longitudinal reinforcement for beam slab is checked or not. Only principal reinforcement is checked

Default Check box YES

Code

9.3.1.1(3)

Figure

Check min. reinforcement area

Description

Setting if minimal reinforcement area of longitudinal reinforcement for beam slab is checked or not.

Default Check box YES

Code

9.3.1.1(1)

Figure

Check max. reinforcement area

Description

Setting if maximal reinforcement area of longitudinal reinforcement for beam slab is checked or not.

Default Check box YES

Code

9.3.1.1(1)

Figure

SCIA web