Description |
Setting if minimal clear bar distance of longitudinal reinforcement for column is checked or not. |
Default | Check box YES |
Code |
8.2(2) |
Figure |
![]() |
Description |
Additional limit for minimal clear bar distance of longitudinal reinforcement for column |
Default | Edit box slc,min = 20 mm |
Code |
8.2(2) |
Figure |
![]() |
Description |
Setting if maximal clear bar distance of longitudinal reinforcement for column is checked or not. |
Default | Check box NO |
Code |
Code-independent |
Figure |
![]() |
Description |
Setting if minimal reinforcement area of longitudinal reinforcement for column is checked or not. |
Default | Check box YES |
Code |
9.5.2(2) |
Figure |
![]() |
Description |
Setting if maximal reinforcement area of longitudinal reinforcement for column is checked or not. |
Default | Check box YES |
Code |
9.5.2(3) |
Figure |
![]() |
Description |
Setting if minimal bar diameter of longitudinal reinforcement for column is checked or not. |
Default | Check box YES |
Code |
9.5.2(1) |
Figure |
![]() |
Description |
Setting if minimal number of bars in circular column is checked or not. |
Default | Check box YES |
Code |
9.5.2(4) |
Figure |
![]() |
Description |
Minimal number of bars in circular column is checked or not. This item is viable if the item above is set to YES |
Default | Edit box; nlc,min = 4 bars |
Code |
9.5.2(4) |
Figure |
![]() |
Description |
Setting if minimal mandrel diameter of stirrups for column is checked or not |
Default | Checkbox NO |
Code |
8.3(2) |
Figure |
- |
Description |
Setting if maximal longitudinal spacing of stirrups is checked or not. |
Default | Check box YES |
Code |
9.5.3(3) |
Figure |
Description |
Setting if minimal diameter of longitudinal bar in column is checked or not. |
Default | Check box YES |
Code |
9.5.3(1) |
Figure |
![]() |
Description |
User defined minimal diameter of longitudinal bar in column; visible if check box above is YES |
Default | Edit box; dsc,min = 6 mm |
Code |
9.5.3(1) |
Figure |
![]() |