Bolt elongation length

The EN 1993-1-8, Art 6.2.4.1 Table 6.2 specifies Lb as the bolt elongation length, taken equal to the grip length (total  thickness of material and washers), plus half the sum of the height of the bolt head and the height of the nut.

Within SCIA Engineer:

Lb = tf+tep+(hh + hn)/2 + alt (twh+twn+tbp)

with:

tf thickness of the column flange
tep thickness of the end-plate
hh height of the bolt head
hn

height of the nut

If relevant also thickness of a washer/s and thickness of a backing plate is added.

twh thickness of the washer at bolt head
twn thickness of the washer at nut
tbp thickness of the backing plate

Similar formulas are being used in case of a splice connection. The thickness of a column flange tf is replaced by the thickness of the additional end-plate tep.

In column base connection the anchor elongation length is calculated according to the formula below: 

Lb = hn)/2 + tbp+tgr+ 8*d + alt (twh)

with:

tbp thickness of the base plate
tgr thickness of the grout layer
d bolt diameter

SCIA web

Downloads