Buckling defaults

The default buckling parameters are used whenever a new aluminium 1D member is input into your project. By default, the new member takes these default parameters. If required, you may later alter these default values and assign specific values to the particular member.

Buckling system relation

zz

System length for buckling around the local zz axis (weak axis). This is usually the length between the points braced in the direction of the local yy axis.

yz

System length for torsional buckling. This is the length between the restraints for torsion.

LTB

System length for lateral-torsional buckling. This is usually the length between the points braced in yy direction (= length between the lateral restraints).

Relative deformation systems relation

def y

System length for deformation in the direction of local yy axis (strong axis).

def z

System length for deformation in the direction of local zz axis (weak axis).

 

ky factor

Calculate

The value of the ky factor is calculated by the program.

Factor

The user defines the value of the factor.

Length

The user inputs the buckling length directly.

kz factor

ditto for kz factor

Influence of load position

This field is relevant for lateral-torsional buckling check. It provides for consideration of destabilising loads in moment factors for LTB.

Destabilising loads are loads that act above the level of the beam’s shear centre and are free to move sideways with the beam as it buckles (and produce a disturbing effect)

The procedure to adjust the buckling defaults
  1. Open service Aluminium:

  1. either using tree menu function Aluminium,

  2. or using menu function Tree > Aluminium.

  1. Select function Beams >Setup and open it.

  2. In the dialogue that appears on the screen, select tab Buckling defaults.

  3. Type required values and select appropriate options.

  4. Confirm with [OK].

SCIA web

Downloads

SCIA is part of the Nemetschek group