Service Concrete Advanced enables the user to display internal forces in members. Internal forces may be displays AS ARE, i.e. as calculated by the solver or they may be recalculated to take account of possible shift of the moment diagram and reduction allowed in the particular national standard (see appropriate parameters in Setup dialogue).
In addition to standard drawing setup parameters, the following parameters are added for the needs of design of concrete beams.
Values |
If ON, labels are attached to the diagram. If OFF, only the diagram without any description is displayed. |
Draw section in labels |
If ON, the longitudinal position of the section is depicted. |
Draw load case or combination in label |
The design is always performed for the selected load case or combination. The number of considered load case / combination may be added to the diagram label. |
Warnings, errors |
If ON, the number of a potential warning or error is attached to the diagram of selected quantity. If no error occurs, nothing is printed. |
Refresh |
Refreshes the contents of the graphical window. Whenever the refresh of the screen is required, this item is red-highlighted. |
Calculation info |
Shows information about the calculation. See separate chapter. |
Concrete setup |
Enables the user to modify design parameters. See separate chapter. |
Preview |
Shows the selected design values in the Preview window. |