The connection may be "stiffened" by a haunch. Such a haunch is used for the purpose of the design and check of the connection (read carefully the note below).
Note: Adds a haunch to the connected beam. This haunch (i) affects the check of the connection, (ii) is taken into account when calculating the "substitute" stiffness of he connection (if option Update stiffness is ON), BUT (iii) is ignored in the calculation model itself (unlike the haunch defined by means of function Structure > Haunch.