Automatic seismic combinations are available in projects calculated according to the EN code. To work properly, it is necessary to have several seismic load cases in the project in a load group with relation set to together.
After adding all Load cases to this combination, SCIA Engineer automatically generates 24 Newmark combinations using this scheme.
It means, every direction of the seismic load is combined with 30% of other directions and these combinations are combined with other permanent and variable load cases.