The procedure used for performing the checking is analogous to the procedure for evaluation of results.
It can be summarised by the following points:
Opening of the required service.
Selection of beams that should be checked.
Selection of load case or load case combination that should be used.
Adjusting of display parameters.
Selection of values to be displayed.
Displaying of the results of the checking.
The required type of check can be selected in the tree menu of service Steel > Beams. Once the type of the check is selected, the appropriate parameters are listed in the Property window.
Parameters common for most of the available check types are:
Selection |
The user may display the results either on all or only selected beams. |
Load type |
Specifies what "load type" is considered for the display. Available load types are: load cases, load case combinations, result classes. |
Load case / combination / class |
For each of the above specified load type a set of available items (load cases, combinations, result classes) is offered. |
Filter |
The set of beams where the results are displayed may be specified by means of a filter. |
Values |
For each of the result groups (unity check, fire resistance check, etc.) a set of quantities is offered for display. The user may select which one is really shown. |
Extreme |
The numerical values may be displayed in specified extreme points. |
Drawing setup |
It is possible to adjust the style of the diagrams. |
Other specific parameters |
Some of the available result groups (unity check, fire resistance check, etc.) may have other group-specific parameters. |
The result diagrams may be displayed on:
all the beams in the structure,
selected beams only.
Which variant is actually applied can be adjusted in the Property window by means of parameters Selection and Filter.
The selection must be ended (using [Esc] key or pop-up menu function End of command) before it may be applied.
Whenever the settings in the Property window of service Check are changed, the diagrams on the screen usually require regeneration. Because the fully automatic regeneration could be very slow for excessive models, it is up to the user to regenerate the drawing when necessary.
Any time the user makes a change that affects the display, the program paints the cell Redraw of the Property window in red colour. Until the user presses the button [Redraw], the cell remains highlighted.
Displaying steel check graphs can be handled by 1D drawing settings.