Angle between concrete compression strut and beam axis perpendicular to the shear force can be calculated automatically or input by user in SEN depending on parameter Type calculation/input angle of compression strut. This parameter can be changed in Concrete setting (if 1D concrete member data is not defined) or in 1D concrete member data. There are the following options:
where
TEd | the design torsional moment |
TRd,max | the design torsional resistance moment |
VEd | the design resultant of shear forces |
VRd,max | design value of the maximum shear force which can be sustained by the member, limited by crushing of the compression struts |
Minimal and maximal angle of compression strut is parameter of national annex and can be edit in Manager of national annex