Mechanical reinforcement ratio - check

Mechanical reinforcement ratio depends on total area of longitudinal reinforcement. For checks total area of reinforcement is calculated from inputted reinforcement via REDES or Free bars. The mechanical reinforcement ratio is calculated according to formula below. The mechanical reinforcement can be different along whole length of the column and in each section of the member and it is calculated according to formula below

ω = ∑(As,i ∙ fyd,i) / (Ac ∙ fcd)

where

As,i cross-sectional area of i-th reinforcement in the cross-section of current section inputted via REDES or Free bars
fyd,i design yield strength of i-th reinforcement in the cross-section inputted via REDES or Free bars inputted via REDES or Free bars
Ac cross-sectional area of concrete cross-section
fcd design value of concrete compressive strength

The coefficient B is than calculated according to formula:


B = √(1 + 2 ∙ ω)