Steel checks

  1. Double-click on the Steel  service in the Main window.


  2. Click on Check from the subgroup ULS Checks of the group Beams in the Steel service.
  1. Define following settings in the Properties window.

    Selection = all
    Type of loads = Combinations
    Filter = No
    Values = un. check
    Extreme = Member
    Output = Detailed
    Section = All

  2. Click Refresh in the Properties window.
  3. Check displayed steel checks values.