Steel code check Setup dialogue - EC-EN

This chapter provides full explanation of individual parameters from the Steel Setup dialogue.

Member Check

Classification

Use Semi-Comp+

Reference

Valorisation Project: SEMI-COMP+ n° RFS2-CT-2010-00023

Description

Setting to use the plastic member capacity of Semi-Compact steel sections.

Application

When this setting is activated, modified classification limits are used for I-section and RHS sections. In addition, when those sections are classified as Class 3 the section moduli are interpolated between the elastic and plastic values in order to use the plastic capacity of the section.

Plastic analysis

Reference

EN 1993-1-1 article 5.2.2

Description

Setting to determine the plastic stress distribution of the cross-section.

Application

The result of the selected approach is used in the calculation of the α-value for the Class 1 & 2 limits.

- Elastic stresses: The elastic stresses are used to calculate the plastic stress distribution using fixed formulas.

- Yield surface intersection: A discrete plastic (yield) surface is derived for the section. The actual internal forces are then scaled until they intersect with that yield surface. The point from the yield surface that is closest to the intersection point is then used for further determination of the plastic stress distribution.

- Iterative approach: The actual forces are increased iteratively and each time the plane of deformation is calculated. In case no plane can be determined the boundary is reached. The approach then goes back one step and used the plane deformation of that step.

Shear

Use Ay, Az instead of elastic shear

Reference

EN 1993-1-1 article 6.2.6(2),(4)

Description

Setting to use the plastic shear check instead of the elastic shear check.

Application

In case a cross-section has no formula defined for the shear area the elastic shear check is executed instead of the plastic one.

When this setting is activated, the plastic shear check is executed instead, using the Ay and Az shear areas defined in the cross-section.

Torsion

Limit for torsion

Reference

EN 1993-1-1 article 6.2.7

Description

Limit value to ignore torsion in combined checks.

Application

In case a member is subject to torsion, but the torsion check remains smaller than the limit set in this field, the torsion is considered as insignificant and is ignored in the combined checks.

Default sway types

y-y

Reference

EN 1993-1-1 article 6.3.1.3

Description

Setting for the sway type y-y.

Application

The sway type is used for determining the appropriate buckling coefficient ky.

z-z

Reference

EN 1993-1-1 article 6.3.1.3

Description

Setting for the sway type z-z.

Application

The sway type is used for determining the appropriate buckling coefficient kz.

Buckling length ratios ky, kz

Max. k ratio

Reference

EN 1993-1-1 article 6.3.1.3

Description

Limit for the buckling ratios for flexural buckling.

Application

Value which serves as a limit for the calculated buckling ratios. The buckling ratios are 'capped' at this value.

Max. slenderness

Reference

EN 1993-1-1 article 6.3.1.3

Description

Limit for the slenderness for flexural buckling.

Application

In case the slenderness for flexural buckling (around either axis) exceeds this limit a warning is shown on the output.

2nd order buckling ratios

Reference

EN 1993-1-1 article 5.2.2(7)b

Description

Setting for buckling ratios in case of 2nd order analysis.

Application

In case of 2nd order analysis this setting is used to determine the buckling ratios:

- According to input: the buckling ratios are the same as for a linear analysis

- All non-sway: Calculated buckling ratios are recalculated using the non-sway setting

- l = L: The buckling length equals the system length

Lateral torsional buckling curves

Lateral torsional buckling curves

Reference

EN 1993-1-1 article 6.3.2.2, 6.3.2.3

Description

Setting for selecting the lateral torsional buckling curves.

Application

Used in the determination of the reduction factor for lateral torsional buckling.

Method for C1, C2, C3

Reference

EN 1993-1-1 article 6.3.2.2 (2)

Description

Setting for selecting the calculation method of the C1 C2 C3 coefficients.

Application

Used in the determination of Mcr, the elastic critical moment for lateral torsional buckling.

- ENV 1993-1-1 Annex F: A tabulated method where the actual moment diagram is compared to standard diagrams.

- ECCS 119/Galea: A graphical method which accounts for interaction between transverse loading and end moments.

- Lopez, Yong, Serna: A closed-form formula for C1 which accounts for the actual moment diagram.

Method for kc

Reference

EN 1993-1-1 article 6.3.2.3 (2)

Description

Setting for selecting the calculation method of the kc correction factor.

Application

Used in the determination of the modified reduction factor for lateral torsional buckling. The kc factor can either be determined from Table 6.6 or derived from C1 which gives a more exact value.

General settings

Elastic verification

Reference

EN 1993-1-1 article 6.2.1 (5)

Description

Setting for performing the Elastic verification.

Application

When this setting is activated, the Elastic verification is performed always, even for sections which could normally be checked using plastic resistances.

Verify only section checks

Reference

EN 1993-1-1 article 5.2.2 (7)a

Description

Setting for only verifying the section checks.

Application

When this setting is activated, no individual stability checks for members are executed. This setting is typically used in case 2nd order effects and imperfections are fully accounted for in the global analysis.

Flexural buckling accounted for by 2nd order calculation

Reference

EN 1993-1-1 article 5.2.2 (7)b

Description

Setting for neglecting flexural buckling checks.

Application

When this setting is activated, flexural buckling is neglected. This setting is typically used in case 2nd order effects and imperfections for flexural buckling are accounted for in the global analysis but torsional and lateral torsional buckling still have to be verified.

Moments on columns in simple construction

Reference

Access-Steel SN005a-EN-EU, SCI Publication P365

Description

Setting to account for moments on columns in simple (pinned floor beam) construction.

Application

When this setting is activated, additional moments are determined within the columns at the position where pinned floor beams are connected. The additional moments are caused by the eccentricity of the pinned connection with respect to the centerline of the column.

Fire resistance

Requirement

Required fire resistance

Reference

EN 1991-1-2 article 2.5

Description

Time during which the member should maintain its load bearing function when exposed to fire.

Application

Used in the final verification of the fire resistance.

Net heat flux

Emissivity related to the fire compartment εf

Reference

EN 1991-1-2 article 3.1(6)

Description

Emissivity related to the fire compartment.

Application

Used in the calculation of the net radiative heat flux component.

Emissivity related to the surface material εm

Reference

EN 1991-1-2 article 3.1(6) and EN 1993-1-2 article 2.2(2)

Description

Emissivity related to the surface material.

Application

Used in the calculation of the net radiative heat flux component.

Configuration factor φ for radiative heat flux

Reference

EN 1991-1-2 article 3.1(6) and (7)

Description

Configuration factor for the radiative heat flux.

Application

Used in the calculation of the net radiative heat flux component.

Temperature-time curve

Temperature-time curve

Reference

EN 1991-1-2 article 3.2

Description

Setting to select the nominal temperature-time curve.

Application

Used for determining the gas temperature at a given time.

Coefficient of heat transfer by convection αc

Reference

EN 1991-1-2 article 3.1(3)

Description

Coefficient of heat transfer by convection.

Application

Used in the calculation of the net convective heat flux component.

Structural fire design

Analysis type

Reference

EN 1991-1-2 article 2.5(2) and EN 1993-1-2 article 4.2.1

Description

Analysis type for the verification of the fire resistance.

Application

The verification of the fire resistance can be executed in the resistance domain, the time domain or the temperature domain.

Use adaptation factor for shadow effect ksh

Reference

EN 1993-1-2 article 4.2.5.1

Description

Setting for taking into account the shadow effect adaptation factor.

Application

Used in the steel temperature development of unprotected internal steelwork.

Cold formed

Local and distorsional buckling

Use manufacturer provided effective section properties

Reference

EN 1993-1-3 article 5.5

Description

Setting to use manufacturer provided effective section properties.

Application

When this setting is activated, effective section properties from the manufacturer are taken from the Effective Section Library instead of calculated by the EN 1993-1-3 calculation methods.

Stiffener iteration

Reference

EN 1993-1-3 article 5.5.3.2(10) and 5.5.3.3(9))

Description

Setting to calculate the stiffeners iteratively during the effective section calculation.

Application

When this setting is activated, an iterative process is used to calculate the effective section of plane elements with edge and/or intermediate stiffeners.

This setting cannot be used in conjunction with the 'Use lambda,p,red' setting of 'Plated structural elements' due to the fact that the stiffener iterations require the use of fyb.

Overall cross-section iteration

Reference

EN 1993-1-3 article 5.2.2(3)

Description

Setting to use iterations over the total cross-section during the effective section calculation.

Application

When this setting is activated, the effective section calculation over the total cross-section is done in an iterative way which uses the effective section of the previous step as starting point for the next iteration.

This setting can only be activated in case also the 'Stiffener iterations' setting is activated.

Local transverse forces

Ignore check

Reference

EN 1993-1-3 article 6.1.7.1(3)

Description

Setting to ignore the Local Transverse Forces check.

Application

When this setting is activated, the Local Transverse Forces check is ignored in the entire project. The check can for example be ignored in case the local load or support reaction is applied through a cleat that is arranged to prevent distortion of the web.

Bearing length Ss

Reference

EN 1993-1-3 article 6.1.7.2

Description

Default value for the nominal length of stiff bearing Ss.

Application

Used in the determination of the Local Transverse Forces resistance as the length over which the local load or support reaction is spread.

Use Ia correction in (6.18)

Reference

Corrections and amendments to EN 1993-1-3, 2010.

Description

Setting to account for a correction of la, the effective bearing length for the relevant category.

Application

Following this reference, using la = 10 mm for the end support reaction force (category 1) results in a very conservative resistance. A modification is given for case 2 and 3 of Figure 6.9: la = c + Ss.

Combined bending and axial compression

Interaction

Reference

EN 1993-1-3 article 6.2.5

Description

Setting to select the interaction method for combined bending and axial compression.

Application

Using this setting either the standard interaction of EN 1993-1-1 article 6.3.3 can be selected or the alternative given in EN 1993-1-3 article 6.2.5(2).

Buckling resistance of the free flange

Limit for large axial force

Reference

EN 1993-1-3 article 10.1.4.2(5)

Description

Limit value to distinguish between a large and small axial force.

Application

Within this article the code specifies a method for the buckling length of the free flange in case of a 'relatively large axial force'. The axial force is considered as 'relatively large' in case the unity check for normal force only exceeds the limit set in this field.

Plated structural elements

Use λp,red

Reference

EN 1993-1-5 article 4.4(4)

Description

Setting to use the reduced relative plate slenderness.

Application

Using this setting the relative plate slenderness is reduced using the ratio between the maximal design compressive stress in the element and the yield strength.

Note

This setting cannot be used in conjunction with the 'Stiffener iterations' setting of 'Cold Formed' due to the fact that the stiffener iterations require the use of fyb.

Use Annex E

Reference

EN 1993-1-5 Annex E article E.1(1)

Description

Setting to use the alternative method for determining the effective section as given in Annex E.

Application

Using this setting the alternative method for determining the effective section at stress levels lower than the yield strength is applied.

Buckling defaults

See Relative deformation parameters

Relative deformation

See Relative deformation parameters

Autodesign

Consider arbitrary members as prismatic for Autodesign

Description

Setting to consider arbitrary members as prismatic during Autodesign.

Application

When this setting is activated, arbitrary members are considered as prismatic, leading to a faster but less accurate Autodesign.