General fire resistance parameters for NEN 6072

The general parameters define applied procedures and specify code-related parameters used throughout the checking of a beam concerning its fire resistance:

temperature curve

Available temperature curves are:

  • ISO 834 curve,

  • external fire curve,

  • hydrocarbon curve,

  • smouldering fire.

correction factor for beam exposed on 3 sides

Adaptation factor for non-uniform temperature distribution across a cross section exposed on three sides.

Default value = 0.70.

correction factor for columns and beams

This value is a correction factor that allows for a number of effects, including the difference in the strain at failure.

The value is empirical.

Default value = 1.2.

analysis type

The fire resistance check can be performed in three domains:

  • strength domain,

  • temperature domain,

  • time domain.

In the resistance domain, the resistance is checked after the imposed time.

In the temperature or time domain, the material temperature (after the imposed time) is checked in relation to the critical material temperature.

iterative process

The critical material temperature is calculated using the analytical formulas of the code, or by an iterative process.

safety factor for fire situation

The partial safety factor for fire situation.

Default value is 1.0.