Grid Pinned connections are beam-to-beam connections. Three main forms are considered in SCIA Engineer:
-
Welded pinned plate
-
Bolted pinned plate
-
Cleat
-
Short end plate
The grid pinned connections are checked for critical shear force and normal force. The following critical situations are considered:
(1) VRd : design shear resistance for the connection element
(2) VRd : design shear resistance of the beam
(3a) VRd : design block shear resistance for beam web
(3b) VRd : design block shear resistance for connection element (beam side)
(3c) VRd : design block shear resistance for connection element (column side)
(3d) VRd : design block shear resistance for endplate (beam side)
(4) VRd : design shear resistance due to the bolt distribution in the beam web
(5) VRd : design shear resistance due to the bolt distribution in the column
(6) VRd : design shear resistance at the notch
(7) NRd : design compression/tension resistance for the connection element
(8) NRd : design compression/tension resistance of the beam
(9) NRd : design tension resistance due to the bolt distribution in the column
[(10) NRd : design compression resistance for column web]