Defining a new damper
A damper can be defined in a support, on a beam membe, on a slab.
Procedure to define a new damper
-
Open service Dynamics.
-
Start function Dampers.
-
If no damping has been defined so far, the Damping groups manager is opened on the screen. Define at least one damping group.
-
The Dampers branch is opened in the tree menu bar.
-
Select and start the function corresponding to the required type of damper:
-
1D damping,
-
2D damping,
-
Node damping.
-
-
Fill in the parameters.
-
Select the appropriate 1D member/slab/support where the damper is to be installed.
-
End the function.
1D damping
Name |
Specifies the name of the damper. |
Type |
Select the type of the damping parameter. Logarithmic decrement Relative damping Rayleigh damping |
Value Alpha / Beta |
Specifies the value of the parameter selected in the item above. Note: The Rayleigh damping requires the definition of two parameters. The remaining two types need just one value. |
2D damping
Name |
Specifies the name of the damper. |
Type |
Select the type of the damping parameter. Logarithmic decrement Relative damping Rayleigh damping |
Value Alpha / Beta |
Specifies the value of the parameter selected in the item above. Note: The Rayleigh damping requires the definition of two parameters. The remaining two types need just one value. |
Node damping
Name |
Specifies the name of the damper. |
Damping X Damping Y Damping Z |
Defines the damping in individual directions of the global coordinate system. |