Maximal longitudinal spacing of stirrups based on shear (9.2.2(6))

The maximal longitudinal spacing between stirrups links should not exceed maximal value defined in 9.2.2(6). Check looks as follows. Calculation of maximal defined longitudinal distance of stirrups sl.

Furthermore maximal allowed longitudinal distance between stirrups is calculated as follows

sl,max = 0,75∙d∙(1+cotg (α))

where:

Finally unity check is calculated as follows:

UC9.2.2(6) = sl/ sl,max.

Clause 9.2.2.(6) - Maximal longitudinal spacing of stirrups for National annex

There are the following differences in particular NA.

National annex

formula
Standard NA 0,75∙d∙(1+cotg (α))
Austrian ÖNORM-EN NA max(0,75∙d∙(1+cotg (α)); 250 mm)
Czech ČSN-EN NA max(0,75∙d∙(1+cotg (α)); 400 mm)
French NF-EN NA

for h ≤ 250 mm

  • sl,max= 0,9∙d

for h > 250 mm

  • sl,max= max(0,75∙d∙(1+cotg (α))
German DIN-EN NA

for VEd≤ 0,3∙VRd,max

  • for fck≤ 50 MPa→ sl,max= max(0,7∙h; 300 mm)
  • for fck> 50 MPa→ sl,max= max(0,7∙h; 200 mm)
  • for VEd< VRd,c; h < 200 mm and beam

  • sl,max= 200 mm

for 0,3•VRd,max< VEd≤ 0,6∙VRd,max

  • for fck≤ 50 MPa → sl,max= max(0,5∙h; 300 mm)
  • for fck> 50 MPa → sl,max= max(0,5∙h; 200 mm)

for VEd> 0,6∙VRd,max

  • sl,max= max(0,25∙h; 200 mm)
Slovak STN-EN NA max(0,75∙d∙(1+cotg (α)); 400 mm)