Checking to interaction diagram
The checking of a concrete member can be carried out (among other methods) using the interaction diagram method. Interaction N + My + Mz, Vz.
Parameters
Values
Check |
the assessment by means of relative value. |
Nu |
ultimate axial force |
Vzu |
ultimate shear force |
Myu |
ultimate bending moment My |
Mzu |
ultimate bending moment Mz |
Note: The values may differ according to the applied code.
Drawing setup
In addition to standard drawing setup parameters, the following parameters are added for the needs of design of concrete beams.
Values |
If ON, labels are attached to the diagram. If OFF, only the diagram without any description is displayed. |
Draw section in labels |
If ON, the longitudinal position of the section is depicted. |
Draw load case or combination in label |
The design is always performed for the selected load case or combination. The number of considered load case / combination may be added to the diagram label. |
Warnings, errors |
If ON, the number of a potential warning or error is attached to the diagram of selected quantity. If no error occurs, nothing is printed. |
Action buttons
Refresh |
Refreshes the contents of the graphical window. Whenever the refresh of the screen is required, this item is red-highlighted. |
Calculation info |
Shows information about the calculation. See Calculation info for design. |
Concrete setup |
Enables the user to modify design parameters. See Concrete setup for design of beams. |
Single check |
Performs a detailed check of a selected beam. See separate chapter. |
Preview |
Shows the selected design values in the Preview window. |