Handling with the function is analogous to Checking of limit strain. The values offered for display are naturally different.
Check value
The result of the check. The value of 1 means that the capacity is fully utilised.
sigma cc,max
Allowable stress of concrete prior and after anchoring/transfer of prestressing.
sigma cc,ch
Allowable stress of concrete in compression under SLS characteristic combination.
sigma cc,qp
Allowable stress of concrete in compression under SLS quasi-permanent combination.
f ct,eff
Allowable stress of concrete in tension under SLS combinations.
sigma c,aa
Stress of concrete after anchoring/transfer of prestressing.
sigma cq,min
Minimum concrete stress after application of self-weight, all permanent, and variable loads.
sigma clt,min
Minimum concrete stress caused by long-term loads.
sigma cq,max
Maximum concrete stress after application of self-weight, all permanent, and variable loads.
sigma clt,max
Maximum concrete stress caused by long-term loads.
sigma c,inc
Stress increment in concrete caused by selected load case.
For the procedure read Performing the check of allowable stress in concrete.