Checking of limit strain

Parameters

Name

Shows the name of the function.

Selection

All

The result diagrams are displayed on all the active members in the structure.

Standard

The result diagrams are displayed on all the currently selected members.

Selected

This option allows the user to display diagrams on selected members. It is similar to the previous option but offers something more. See below the table.

Named selection

This option allows the user to select one of the previously created, named and saved selections.

Type of load

This item selects the type of load for which the results are to be displayed: load cases, combinations, result classes.

If any of the option is marked with an asterisk, the results for that option are not available.

Load case/Combination/Class

Depending on the option selected in the previous item, this combo box offers the available load cases/combinations/classes.

Filter

This option enables the user to filter the members on which the results will be displayed.

Print explanation

If ON, the output in the Preview window (invoked by action button [Preview]) shows the explanation of possible errors and warnings encountered during the calculation.

Values

This combo offers the available result quantities.

Extreme

This item control the display of numerical values attached to the result diagram.

Drawing setup

Read chapter Results > Adjusting the style of result diagrams in the Reference Guide.

Section

Read chapter Results >Selected sections >Displaying the results in selected sections in the Reference Guide.

 

Selection: Selected

With this option, you may select required members on which the results are to be displayed and review the results. Then you may clear the selection. The result diagrams, however, remain displayed. Now you may make a new selection and invoke the refresh of the screen. The program will ask you what to do. The available options are:

Use current selection

The result diagrams displayed during the last refresh are deleted. New result diagrams are displayed on the currently selected members only.

Add current selection to previous selection

The result diagrams displayed during the last refresh remain displayed. New result diagrams are shown on the currently selected members.

Use previous selection

The current selection is ignored. The result diagrams displayed during the previous refresh remain displayed.

Subtract current selection from previous selection

If there is a result diagram currently displayed on one of the currently selected members, this diagram is hidden. The result diagrams that are shown on members that are not in the current selection remain displayed.

Values

check value

the assessment by means of relative value

eps cc

concrete strain

eps sc

reinforcement steel strain – compression

eps st

reinforcement steel strain – tension

eps tt

tendon strain – tension

Vzu

shear resistance

T u

torsional resistance

Vrdi

design shear resistance at the interface

Action buttons

Refresh

Refreshes the screen.

Calculation info

Show a brief information about the calculation of the result quantities.

Concrete setup

Open the Setup dialogue.

Single check

Calls the Detailed checking of limit strain.

Preview

Shows result table(s) in the Preview window.

For the procedure read Performing the checking of limit strain.

 